• PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
  • PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
  • PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
  • PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
  • PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
  • PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing

PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing

Capacity: Four Person
After-sales Service Provided: Engineers available to service machinery overseas
Certification: CE, ISO9001
Usage: Research Institute, Hospital, School
Noise: ≤62DB
Type: for P2&Nuclein Acid Testing
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Rating: 5.0/5
Jiangsu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (14)

Basic Info.

Model NO.
JH-PCR01
Application Location
Hospital/Research Institue/Custom etc
Transport Package
Carton, Wooden Case
Specification
custom made
Trademark
GLORYLAB
Origin
China
HS Code
9403200000
Production Capacity
1000 Sets/Month

Product Description


Product name: PCR Lab Mobile 40HQ Container Laboratory for Nuclein Acid Testing
External Dimensions:12.192*2.438*2.896m (length*width*height)
Interal Dimensions: 11.8*2.3*2.6m (length*width*height)
Occupied Area: 29.7m2,about 5 standard car parking spaces

PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
Advantage: Modular and integrated supporting equipment provided by factory. Ready for use. No need for secondary installation. Emergency construction achieved efficiently.

Application location:  Hopital, port, healthcare institue, custom.

Construction standard:

<<Technical standards for construction of secondary laboratories for medical biosafety>>T/CECS662G-2020
<<Design specification for heating ventilation and air conditioning in civil buildings>>GB50736
<<Acceptance specifications for clean room>>GB50591
<<US standard for laboratory grade metal casework>> SEFA8M-2016


Composite of PCR Container Mobile Lab

1. 1x40HQ customized container with door&window
2. Customized steel laboratory furniture, with necessary lab fitting such as sink, lab faucet etc.
3. Basic container configuration: It's consist of partition&floor, pipe&electricity&auto control system etc satisfying the basic needs of a mobile PCR lab
4.
Full set of lab testing equipments, mainly including laminar flow cabinet,water purifier,refrigerator, biosafety cabinet, Nucleic acid extraction system,PCR detection system,high-end waste liquid collection system etc. 

Remark: PCR lab can be ordered separately without lab instruments.

PCR laboratory workflow: detection scope, detection process and detection quality are constantly developing and changing. In this process, the transmission route and pathogenicity of the disease have not been completely defined, and biosafety issues in the detection process and infection risk of the detection personnel need to be guided to a certain extent.

Experimental process: specimen transport and  receipt-specimen  pretreating-nucleic  acid  extraction  and  sampling-nucleic
acid


Flow direction: PCR corridor - buffer room - experimental processing room (reagent preparation  room,  specimen  preparation room, amplification&analysis room, decontamination room)

Article direction: reagent preparation room - specimen preparation  room -  amplification  &  analysis  room -  decontamination room

For technical information, pls contact with us for detailed catalogue&vedio.

PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing
PCR Lab Mobile 40hq Container Laboratory for Nuclein Acid TestingPCR Lab Mobile 40hq Container Laboratory for Nuclein Acid Testing

Note:


1. Access to each working area should be carried out strictly in a  single  direction, that is,  reagent  preparation room -  specimen preparation room - amplification & analysis room-Washing room.

2. Each work area must be clearly marked and equipment and articles in different work areas must not be mixed.

3. Use different uniforms in different work areas.

4. The  cleaning  of  the  laboratory  should  follow  the  direction  of  reagent  preparation  area -  specimen   preparation  area - amplification&analysis area.Different test areas shall have their own cleaning apparatus to prevent cross contamination.

5. Clean the work area immediately after work.


 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001